NEW Lombardini LMG9000 10kVA Marine Diesel Generator Package
$13,243.00
- Description
- Reviews (0)
Description
New Lombardini LMG9000 10 kVA Marine Diesel Generator Package For Sale
Complete 8 kW Onboard Power Package for Yachts and Professional Vessels
The New Lombardini LMG9000 10 kVA Marine Diesel Generator Package is a compact, sound-enclosed marine diesel generator set designed to provide dependable onboard electricity for motor yachts, sailing yachts, cruising catamarans, liveaboard boats, passenger craft, workboats, and other professional marine applications.
Powered by the proven Lombardini LDW 702 MG diesel engine, the LMG9000 combines a compact twin-cylinder diesel platform, synchronous alternator, automatic voltage regulation, full-water marine cooling, remote-control operation, automatic engine protection, anti-vibration mounting, practical maintenance access, and a soundproof enclosure in one integrated package.
The generator supplies 10 kVA or 8 kW of continuous electrical power at 230V, single phase, and 50 Hz while operating at 3000 RPM. Its output makes it suitable for compatible marine air-conditioning equipment, refrigeration systems, battery chargers, freshwater pumps, water makers, navigation electronics, communication systems, lighting, entertainment equipment, galley appliances, and other important onboard loads. (Lombardini Marine)
The LMG9000 provides more electrical capacity than the compact LMG4000 and LMG6000 generator packages while remaining smaller and lighter than the larger LMG14000 and LMG18000 models. This makes it a practical onboard marine power solution for vessels requiring more than basic battery charging and lighting without installing an unnecessarily large generator.
Customers considering the Lombardini LMG9000 price should evaluate the complete package rather than comparing electrical output alone. The engine platform, alternator design, voltage regulation, marine cooling system, sound enclosure, remote controls, maintenance access, installation compatibility, and long-term support all contribute to the generator’s overall value.
Purpose-Built Lombardini Marine Generator Package
The Lombardini Marine LMG Series is engineered specifically for onboard electrical generation. Unlike portable or standard industrial generators adapted for vessel use, the LMG9000 integrates the diesel engine, marine alternator, cooling arrangement, electrical controls, safety shutdown systems, vibration isolation, and acoustic enclosure into a purpose-built marine generator package.
The generator is designed for marine conditions that may include:
- Continuous vessel vibration
- High humidity
- Salt-laden air
- Restricted machinery-space ventilation
- Changing electrical demand
- Vessel movement and inclination
- Extended operation away from shore power
The LMG9000 uses an engine from Lombardini’s FOCS family. Lombardini describes the FOCS generator engines used in the LMG9000, LMG14000, and LMG18000 as compact platforms developed for reduced noise, low vibration, and low emissions. (Lombardini Marine)
Its integrated sound enclosure, remote-control system, external anti-vibration mounts, cooling equipment, and accessible maintenance layout help simplify installation in compatible yacht and commercial-vessel machinery spaces.
Selecting the correct yacht generator package involves more than matching the rated output to the combined wattage of onboard equipment. Continuous electrical demand, compressor startup loads, motor-starting current, installation dimensions, ventilation, seawater supply, exhaust routing, fuel requirements, expected operating hours, and future electrical additions should all be reviewed before purchase.
Lombardini LDW 702 MG Twin-Cylinder Diesel Engine
The LMG9000 is powered by the Lombardini LDW 702 MG marine diesel engine, a compact twin-cylinder, four-stroke platform designed to provide dependable mechanical power for sustained onboard electricity generation.
Its principal engine characteristics include:
- Two cylinders in line
- Four-stroke diesel operation
- Approximately 686 cm³ displacement
- Approximately 11 kW mechanical output
- 3000 RPM operating speed
- Indirect cooling through a marine heat exchanger
- 12V electric starting
- Remote-controlled starting and stopping
The twin-cylinder arrangement provides smoother operation than many compact single-cylinder generator platforms while maintaining dimensions suitable for space-conscious installations.
Its approximately 11 kW mechanical output provides sufficient capacity to produce 10 kVA or 8 kW of continuous electrical power in the standard 50 Hz configuration.
Potential advantages of the LDW 702 MG diesel platform include:
- Compact engine dimensions
- Smooth twin-cylinder operation
- Reduced vibration
- Proven Lombardini diesel engineering
- Practical routine maintenance
- Dependable power under changing electrical loads
- Suitability for recreational and professional vessels
A correctly sized diesel marine generator allows vessel owners to operate important electrical equipment while cruising, remaining at anchor, or working offshore without relying continuously on marina electricity.
It may also reduce the need to run the vessel’s main propulsion engine solely for battery charging or auxiliary electrical production.
10 kVA and 8 kW Continuous Electrical Output
Understanding the difference between kVA and kW is important when selecting a marine diesel generator package.
| Electrical Specification | Rating |
|---|---|
| Apparent Electrical Power | 10 kVA |
| Active Electrical Power | 8 kW |
| Voltage | 230V |
| Frequency | 50 Hz |
| Electrical Configuration | Single Phase |
| Operating Speed | 3000 RPM |
| Starting System | 12V Electric Start |
The 10 kVA rating represents apparent electrical power, while the 8 kW rating represents active electrical output available under the manufacturer’s stated operating conditions. Lombardini currently lists the LMG9000 as a 10 kVA, 8 kW generator operating at 3000 RPM. (Lombardini Marine)
The vessel’s sustained electrical load should remain within the approved generator capacity while preserving reasonable reserve for temporary demand increases and equipment startup requirements.
Equipment containing electric motors or compressors may draw substantially more current during startup than during normal operation. This commonly applies to:
- Marine air-conditioning compressors
- Refrigeration and freezer systems
- Freshwater and seawater pumps
- Water-making equipment
- Battery chargers
- Ventilation motors
- Galley appliances
- Other motor-driven machinery
Selecting a generator that is too small may result in:
- Electrical overload
- Voltage instability
- Difficulty starting motors and compressors
- Excessive operating temperature
- Frequent protective shutdowns
- Reduced generator service life
However, selecting a generator that is substantially larger than required may result in prolonged operation under very light electrical load.
A professional marine electrical load assessment helps determine the correct balance between continuous demand, startup requirements, operating reserve, and future equipment additions.
Stable 230V Single-Phase Marine Electricity
This LMG9000 package is configured to supply dependable 230V single-phase marine power at 50 Hz.
Single-phase electricity is widely used aboard recreational and professional vessels for domestic appliances, charging systems, navigation electronics, lighting, refrigeration, climate-control equipment, and other onboard services.
The generator may support compatible equipment such as:
- Marine battery chargers
- Refrigerators and freezers
- Compact air-conditioning systems
- Freshwater pumps
- Navigation electronics
- Communication systems
- Lighting circuits
- Electrical outlets
- Entertainment equipment
- Galley appliances
- Vessel-monitoring systems
Lombardini also lists the LMG9000 platform in alternative electrical configurations, so voltage and phase should be confirmed before ordering. (Lombardini Marine)
Before installation, a qualified marine electrician should verify:
- Generator voltage
- Electrical frequency
- Cable sizes
- Earthing and bonding
- Circuit-breaker ratings
- Shore-power integration
- Transfer-switch arrangement
- Switchboard compatibility
- Expected operating demand
The vessel’s shore-power supply and generator should not energise the AC distribution system simultaneously. A correctly rated manual or automatic changeover arrangement should isolate the power sources safely.
Synchronous Alternator with AVR Voltage Regulation
The LMG9000 uses a synchronous marine alternator combined with an automatic voltage regulator.
Lombardini states that the alternator provides constant voltage from zero load up to rated output through its AVR system. This helps support stable electricity as connected demand changes. (Lombardini Marine)
Stable voltage is especially important for compatible:
- Navigation electronics
- Communication systems
- Battery chargers
- Refrigeration controllers
- Vessel-monitoring equipment
- Entertainment electronics
- Pumps and electric motors
Potential advantages of the AVR-regulated alternator include:
- Stable output voltage
- Reliable performance under changing load
- Suitable power for compatible marine electronics
- Improved motor and compressor operation
- Better support for battery-charging equipment
Reliable onboard electricity depends on the complete installation rather than the alternator alone. Correct wiring, grounding, cable sizing, circuit protection, transfer switching, and load management all contribute to dependable performance.
Full-Water Marine Cooling System
A major feature of the LMG9000 package is its full-water marine cooling system.
The generator uses seawater through a dedicated cooling arrangement to help control the temperature of:
- The engine’s freshwater cooling circuit
- Engine lubricating oil
- External alternator-stator surfaces
- Water-cooled exhaust components
This integrated arrangement helps manage heat inside enclosed machinery spaces and supports dependable generator performance under sustained electrical demand.
A properly maintained marine generator cooling system supports:
- Stable engine temperature
- Reliable alternator performance
- Efficient heat transfer
- Reduced thermal stress
- Consistent electrical output
- Longer generator service life
Routine maintenance should include inspection of:
- Raw-water intake
- Seawater strainer
- Raw-water pump impeller
- Cooling-water flow
- Engine coolant level and condition
- Heat-exchanger surfaces
- Cooling hoses and clamps
- Exhaust elbow
- Wet-exhaust connections
- Siphon-break arrangement
Restricted seawater flow, a blocked strainer, damaged impeller, insufficient coolant, or inadequate machinery-space ventilation may cause overheating even when the generator is operating within its approved load.
Where the generator is installed below the vessel’s waterline, the seawater and wet-exhaust systems should be evaluated for siphoning risk.
Remote-Control System and Automatic Engine Protection
The LMG9000 package includes a remote generator control panel connected by a plug-in cable. This allows the generator to be started, stopped, and monitored from a convenient location outside the machinery compartment.
The control system may display:
- Generator output voltage
- Generator output current
- Starting-battery voltage
- Accumulated operating hours
- Maintenance information
- High cooling-water temperature warning
- Low engine-oil pressure warning
An automatic shutdown system protects the generator when abnormal oil-pressure or cooling-temperature conditions are detected.
Lombardini’s product literature for the larger LMG models describes remote-control operation and automatic protection as key elements of the package. The precise supplied cable length should be confirmed on the current quotation because different documents and production configurations may vary. (Lombardini Marine)
The operating-hour display helps owners and engineers plan servicing according to the recommended maintenance schedule.
Automatic safety protection provides important safeguards but does not replace routine inspection of engine oil, coolant, seawater flow, fuel supply, filters, electrical connections, ventilation, and exhaust components.
Soundproof Enclosure for Improved Onboard Comfort
The LMG9000 package includes a soundproof marine generator enclosure designed to reduce airborne diesel-engine and alternator noise.
The enclosure helps limit:
- Diesel-engine operating noise
- Alternator noise
- Mechanical generator noise
- Machinery-space sound transmission
- Noise reaching cabins and living areas
A properly installed quiet marine generator should also include:
- Flexible anti-vibration mounts
- Adequate machinery-space ventilation
- Correctly supported hoses and electrical cables
- A professionally designed wet-exhaust system
- Suitable machinery-space insulation
- Adequate service clearance
Final onboard sound levels depend on more than the enclosure. Hull construction, generator mounting, exhaust routing, ventilation openings, compartment insulation, and structural vibration transfer all influence acoustic performance.
Compact Installation and Practical Service Access
The LMG9000 is designed to provide useful electrical capacity while remaining suitable for many yacht and small commercial-vessel machinery spaces.
Published reference specifications commonly identify approximate enclosed dimensions of:
| Measurement | Specification |
|---|---|
| Length | Approximately 780 mm |
| Width | Approximately 480 mm |
| Height | Approximately 590 mm |
| Sound-Enclosed Weight | Approximately 178 kg |
Final dimensions and weight should be confirmed using the approved installation drawing supplied with the quotation, as production specifications may change.
The package is designed with external anti-vibration mounts and dedicated access points for:
- Electrical wiring
- Seawater connections
- Fuel supply and return
- Exhaust routing
- Remote-control cable
- Routine servicing
Important maintenance components are arranged for practical access, helping simplify oil changes, filter servicing, cooling-system inspection, and general preventive maintenance.
Before installation, the vessel owner, boat builder, or marine engineer should confirm:
- Generator dimensions
- Dry and operational weight
- Mounting-point locations
- Machinery-space access
- Service clearances
- Ventilation requirements
- Seawater inlet location
- Exhaust-hose routing
- Fuel-line connections
- Electrical cable access
- Remote-control cable routing
- Lifting and future removal space
When replacing an existing boat generator, matching only the electrical output is not sufficient. Voltage, frequency, dimensions, weight, mounting arrangements, cooling requirements, exhaust routing, fuel-system compatibility, and switchboard integration should also be reviewed.
Operation While the Vessel Is Inclined
Marine generators may be required to operate while the vessel is rolling, pitching, or sailing under heel.
Lombardini’s LMG Series documentation states that the generator range can operate continuously at lateral or longitudinal inclinations of up to 25 degrees and intermittently at inclinations of up to 30 degrees. (Lombardini Marine)
This capability may be useful aboard:
- Sailing yachts operating under heel
- Motor yachts navigating rough conditions
- Cruising catamarans operating offshore
- Professional vessels exposed to regular movement
Correct installation remains essential to preserve lubrication, fuel delivery, cooling-water circulation, and wet-exhaust performance during vessel movement.
Applications of the Lombardini LMG9000 Package
Motor Yachts
The LMG9000 may support compatible air-conditioning systems, refrigeration equipment, battery chargers, freshwater pumps, water makers, lighting, entertainment equipment, galley appliances, and navigation electronics.
Sailing Yachts and Cruising Catamarans
The generator can provide dependable auxiliary marine power for refrigeration, charging systems, freshwater equipment, communications, navigation electronics, lighting, and domestic onboard loads.
Liveaboard Vessels
Its 8 kW active output may support refrigeration, battery banks, water systems, electrical outlets, galley appliances, lighting, and selected comfort equipment during extended periods away from shore power.
Workboats and Professional Craft
The LMG9000 may serve as a compact commercial marine generator for pumps, communication systems, refrigeration, lighting, ventilation equipment, charging systems, and routine operating loads.
Passenger and Hospitality Vessels
The generator may support compatible refrigeration, lighting, ventilation systems, galley appliances, battery chargers, and passenger-service equipment.
Marine Refit Projects
The LMG9000 may be considered when replacing an ageing, inefficient, undersized, or unreliable generator, provided the vessel’s electrical and installation requirements are compatible.
Technical Specifications of the Lombardini LMG9000
| Specification | Details |
|---|---|
| Brand | Lombardini Marine |
| Generator Series | LMG |
| Generator Model | LMG9000 |
| Generator Category | Marine Diesel Generator Package |
| Apparent Electrical Power | 10 kVA |
| Active Electrical Power | 8 kW |
| Voltage | 230V |
| Frequency | 50 Hz |
| Electrical Configuration | Single Phase |
| Operating Speed | 3000 RPM |
| Engine Manufacturer | Lombardini Marine |
| Engine Model | LDW 702 MG |
| Engine Configuration | Two Cylinders, Inline |
| Engine Cycle | Four-Stroke Diesel |
| Engine Displacement | Approximately 686 cm³ |
| Engine Power | Approximately 11 kW |
| Starting System | 12V Remote-Controlled Electric Start |
| Alternator Type | Synchronous Marine Alternator |
| Voltage Regulation | AVR |
| Cooling System | Full-Water Marine Cooling |
| Exhaust System | Marine Wet Exhaust |
| Remote-Control Panel | Standard |
| Automatic Safety Shutdown | Standard |
| Anti-Vibration Mounts | Standard |
| Soundproof Enclosure | Included |
| Approximate Dimensions | 780 × 480 × 590 mm |
| Approximate Enclosed Weight | 178 kg |
| Application | Yacht, Catamaran and Professional Marine Use |
Lombardini’s current product listing identifies the LMG9000 as a 10 kVA, 8 kW marine generator operating at 3000 RPM, while the official LMG range materials confirm its FOCS engine platform and AVR-regulated alternator. (Lombardini Marine)
Standard Equipment Included in the LMG9000 Package
The Lombardini LMG9000 marine generator package is supplied as an integrated onboard power system.
Typical package equipment may include:
- Lombardini LDW 702 MG diesel engine
- Synchronous AVR-regulated marine alternator
- Full-water marine cooling system
- Marine heat exchanger
- 12V electric-starting system
- Remote-control panel
- Plug-in remote-control cable
- Automatic engine-protection system
- Low oil-pressure warning
- High cooling-water temperature warning
- Output-voltage display
- Output-current display
- Starting-battery voltage display
- Generator operating-hour meter
- Anti-vibration mounting equipment
- Soundproof enclosure
Available installation accessories may include:
- Additional remote-control panel
- Fuel-water separator
- Fuel pre-filter
- Seawater strainer
- Siphon-break equipment
- Wet-exhaust components
- Starting battery and cables
- Shore-power changeover equipment
- Additional marine installation accessories
The exact package contents should be confirmed during quotation because production specifications, regional configurations, and vessel requirements may vary.
Genuine Lombardini Generator Supply and Worldwide Support
Customers looking for the New Lombardini LMG9000 10 kVA Marine Diesel Generator Package for sale can contact our marine generator specialists for current availability, technical guidance, installation documents, and international delivery assistance.
We support customers with:
- Genuine Lombardini marine generator supply
- Electrical-load and generator-sizing guidance
- Marine application recommendations
- Replacement-generator assessments
- Technical and installation documentation
- Export documentation
- Worldwide shipping arrangements
- After-sales customer support
Frequently Asked Questions
What is the Lombardini LMG9000 price?
The Lombardini LMG9000 price depends on current availability, selected installation accessories, shipping destination, export requirements, and delivery arrangements. Contact our team for an updated quotation.
How much electrical power does the LMG9000 provide?
The generator provides 10 kVA or 8 kW of continuous electrical power at 3000 RPM. (Lombardini Marine)
Is the Lombardini LMG9000 single phase?
This package is configured for 230V single-phase marine electricity at 50 Hz. Alternative electrical versions may also be available, so the required configuration should be confirmed before ordering. (Lombardini Marine)
What engine is used in the LMG9000?
The generator uses the Lombardini LDW 702 MG, a twin-cylinder diesel engine from Lombardini’s compact FOCS family.
Does the LMG9000 use AVR voltage regulation?
Yes. Its synchronous alternator uses an automatic voltage regulator designed to maintain stable voltage from low load to rated output. (Lombardini Marine)
Is the generator water cooled?
Yes. The LMG9000 uses a marine cooling arrangement designed to manage the engine and alternator temperatures during onboard operation.
Does the package include remote control?
Yes. The package includes remote generator operation and automatic safety monitoring. The exact remote-cable length should be confirmed on the quotation.
Is the LMG9000 sound enclosed?
Yes. The generator package includes a soundproof enclosure designed to reduce airborne operating noise.
Can the LMG9000 replace an existing yacht generator?
Yes. It may be suitable for a marine generator replacement when output, voltage, frequency, dimensions, mounting, cooling, exhaust, fuel, and electrical requirements are compatible.
Is worldwide shipping available?
Yes. We support international marine generator supply, export documentation, and worldwide shipping arrangements.
Request a Quote for the Lombardini LMG9000 Generator Package
The New Lombardini LMG9000 10 kVA Marine Diesel Generator Package is a dependable choice for yacht owners, boat builders, marine installers, shipyards, and professional operators requiring compact single-phase marine power from a sound-enclosed diesel generator system.
Its 10 kVA output, Lombardini LDW 702 MG twin-cylinder engine, AVR-regulated alternator, marine cooling system, remote controls, automatic protection, vibration isolation, and acoustic enclosure make it suitable for a broad range of recreational and professional vessel applications.
Contact our marine generator specialists to request the latest Lombardini LMG9000 price, confirm current availability, review installation requirements, and receive assistance selecting the correct generator package for your vessel.