Nanni Generator Type QLS 102T (Mechanical)
$101,533.00
- Description
- Reviews (0)
Description
New Nanni Generator Type QLS 102T Mechanical Marine Generator For Sale
Heavy-Duty Three-Phase Marine Power for Commercial and Professional Vessels
The Nanni QLS 102T Mechanical Marine Generator is a heavy-duty three-phase marine diesel generator developed for commercial vessels, large motor yachts, expedition craft, passenger boats, offshore-support vessels, and other demanding professional marine applications. Built around a six-cylinder John Deere diesel engine, the QLS 102T combines substantial electrical capacity, mechanically controlled fuel delivery, low-speed operation, and purpose-built marine engineering.
Nanni lists the QLS 102T as a 400V, 50 Hz three-phase generator operating at 1500 RPM. Its published prime rating is 84.6 kW, equivalent to approximately 102.6 kVA at a 0.8 power factor. The generator is intended for vessels requiring dependable electrical power for pumps, refrigeration equipment, hydraulic systems, ventilation machinery, battery chargers, galley equipment, navigation electronics, and other high-demand onboard loads.
The QLS range was developed to power demanding equipment that may be sensitive to voltage variations. Nanni describes these generator sets as using compact, mechanically robust alternators intended for marine duty. (nannidiesel.eu)
Selecting the correct marine generator involves more than comparing output ratings. Vessel owners, shipyards, and marine engineers should also evaluate continuous demand, motor-starting loads, phase balance, available installation space, ventilation, seawater supply, exhaust routing, operating hours, and future electrical requirements.
Mechanical John Deere Diesel Engineering
The Nanni QLS 102T marine generator uses a six-cylinder, inline John Deere diesel engine with approximately 6.8 litres of displacement. The engine is turbocharged, uses direct fuel injection, and operates with a mechanical fuel-control system rather than electronically managed common-rail injection.
This mechanical configuration may appeal to operators who prioritize:
- Straightforward fuel-system architecture
- Familiar mechanical servicing procedures
- Reduced dependence on complex electronic fuel controls
- Practical troubleshooting in remote locations
- Durable operation in commercial marine environments
Mechanical fuel control does not remove the need for correct maintenance. Fuel cleanliness, filtration, injector condition, pump calibration, lubrication, cooling performance, and regular inspection remain essential to dependable service.
The engine operates at 1500 RPM, supporting stable 50 Hz electricity through a low-speed generator arrangement. Compared with many 3000 RPM units, lower rotational speed can help reduce mechanical wear, vibration, and operating noise while supporting extended marine use.
Customers evaluating the Nanni Generator Type QLS 102T Mechanical price should consider more than the initial purchase cost. Generator capacity, fuel-system simplicity, installation compatibility, cooling requirements, service access, expected operating hours, and long-term parts support all contribute to its overall value.
Prime and Published Operating Ratings
Nanni’s published QLS product guide identifies the QLS 102T with the following ratings:
| Electrical specification | Published rating |
|---|---|
| Prime power | 84.6 kW / 102.6 kVA |
| Additional published power rating | 59 kW / 72 kVA |
| Voltage | 400V |
| Frequency | 50 Hz |
| Electrical configuration | Three phase |
| Power factor | 0.8 |
| Operating speed | 1500 RPM |
These figures are shown in Nanni’s QLS generator table. Because the older product guide presents two power rows whose intended duty classifications are not fully explained in the extracted table, the applicable continuous, prime, or limited-time duty rating should be confirmed on the current quotation and model-specific technical sheet before installation.
This confirmation is important because generator selection should be based on the correct duty rating, not simply the highest published number.
A professional marine electrical load assessment should include:
- Normal continuous electrical demand
- Simultaneous equipment operation
- Motor and compressor starting current
- Battery-charging loads
- Hydraulic and pump-system demand
- Emergency and safety-system requirements
- Reasonable future expansion capacity
An undersized generator may experience overload, voltage instability, excessive heat, difficulty starting motors, and premature wear. An excessively oversized generator may spend prolonged periods operating at very light load. Correct sizing helps balance capacity, efficiency, and equipment life.
Three-Phase Power for Demanding Vessel Equipment
The QLS 102T is designed for vessels requiring dependable 400V three-phase marine power. Three-phase systems distribute electrical power efficiently to compatible motors, pumps, compressors, and auxiliary machinery.
The generator may support compatible equipment such as:
- Seawater and freshwater pumps
- Refrigeration and cold-storage systems
- Ventilation and extraction machinery
- Hydraulic power units
- Water-making equipment
- Battery-charging systems
- Commercial galley machinery
- Workshop tools
- Deck and auxiliary equipment
- Navigation and communication systems
- Passenger-comfort equipment
Before installation, a qualified marine electrician should verify voltage, frequency, phase rotation, earthing arrangements, cable sizes, circuit protection, switchboard compatibility, and load distribution.
Single-phase equipment may be supplied through a properly designed three-phase system, but loads should be balanced carefully across all phases. Excessive imbalance can reduce usable generator capacity and affect voltage stability.
Stable Electrical Power for Sensitive Equipment
The wider QLS range was developed to supply equipment that may be sensitive to voltage variation. Nanni highlights the use of compact and mechanically robust alternators across this generator family. (nannidiesel.eu)
A stable vessel power-generation system is important for equipment such as:
- Navigation electronics
- Communication systems
- Vessel-monitoring equipment
- Control panels
- Battery chargers
- Refrigeration controls
- Pumps and motor starters
- Safety and alarm systems
Actual electrical quality depends on more than the generator itself. Correct voltage regulation, engine-speed stability, cable sizing, grounding, protection settings, load balance, and switchboard design all influence onboard performance.
The final installation should therefore be completed and commissioned by qualified marine professionals.
Marine Cooling for Extended Operation
Reliable cooling is essential for dependable marine generator performance. Marine generators normally operate inside enclosed machinery spaces where heat must be removed efficiently.
A correctly engineered installation should include:
- Closed engine-coolant circulation
- Marine heat-exchanger cooling
- Raw-water supply
- Proper seawater filtration
- Wet-exhaust routing
- Adequate machinery-space ventilation
- Correct exhaust back pressure
A properly maintained marine generator cooling system supports stable engine temperature, reliable operation under sustained loads, reduced thermal stress, and longer component life.
Routine inspections should cover coolant condition, raw-water strainers, seawater flow, hoses, clamps, belts, pump impellers, heat-exchanger surfaces, and exhaust components.
Restricted seawater flow, damaged impellers, blocked cooling passages, or inadequate ventilation can cause overheating even when the generator is correctly sized.
Where installation is below the vessel’s waterline, the exhaust and seawater system should be assessed for siphoning risk. A correctly positioned siphon break may be required depending on the installation arrangement.
Installation Dimensions and Machinery-Space Planning
Nanni’s published QLS table lists the QLS 102T with approximate dimensions of:
| Measurement | Specification |
|---|---|
| Length | 1798 mm |
| Width | 693 mm |
| Height | 1097 mm |
| Dry weight | 1273 kg |
These figures come from Nanni’s published product guide and should be treated as reference values. Final installation planning should use the approved model-specific drawing supplied with the quotation.
Before ordering, the installation team should confirm:
- Generator footprint
- Mounting-point positions
- Dry and operational weight
- Service clearances
- Lifting and access routes
- Ventilation requirements
- Seawater inlet location
- Exhaust outlet arrangement
- Fuel supply and return connections
- Main power-cable access
- Future generator-removal space
The Nanni QLS 102T generator set may be suitable for new vessel construction, commercial refits, high-capacity electrical upgrades, and replacement of older mechanical marine generators.
When replacing an existing boat generator, matching only the output is not sufficient. Voltage, frequency, phase configuration, physical dimensions, cooling capacity, exhaust routing, fuel-system compatibility, switchboard design, and maintenance access must also be verified.
Applications of the Nanni QLS 102T Mechanical Generator
Commercial Workboats
The generator can support hydraulic systems, pumps, refrigeration equipment, workshop machinery, lighting, communication systems, and daily operational loads.
Passenger and Hospitality Vessels
Its substantial three-phase capacity may support ventilation, refrigeration, galley equipment, lighting, pumps, battery charging, and passenger-comfort systems.
Expedition and Long-Range Vessels
The QLS 102T may provide dependable auxiliary marine power for vessels operating for extended periods away from shore facilities.
Large Yachts
Compatible large motor yachts and expedition yachts may use the generator for air conditioning, water makers, refrigeration, pumps, galley equipment, charging systems, and onboard services.
Offshore-Support Craft
The generator may support deck equipment, hydraulic power units, pumps, workshop tools, communication systems, and other professional marine machinery.
Marine Refit Projects
The mechanical fuel system may make the QLS 102T attractive for operators replacing an older generator who prefer practical mechanical servicing and established diesel technology.
Technical Specifications of the Nanni QLS 102T Mechanical
| Specification | Details |
|---|---|
| Brand | Nanni |
| Generator Series | QLS |
| Model | QLS 102T |
| Generator Category | Mechanical Marine Diesel Generator |
| Prime Power | 84.6 kW / 102.6 kVA |
| Additional Published Rating | 59 kW / 72 kVA |
| Voltage | 400V |
| Frequency | 50 Hz |
| Electrical Configuration | Three Phase |
| Power Factor | 0.8 |
| Operating Speed | 1500 RPM |
| Engine Base | John Deere |
| Engine Configuration | Six Cylinders, Inline |
| Engine Cycle | Four-Stroke Diesel |
| Displacement | Approximately 6.8 Litres |
| Fuel System | Mechanical |
| Injection System | Direct Injection |
| Air Intake | Turbocharged |
| Approximate Dimensions | 1798 × 693 × 1097 mm |
| Approximate Dry Weight | 1273 kg |
| Application | Yacht, Workboat and Commercial Marine Use |
These specifications are based on Nanni’s published QLS generator guide. Final ratings, alternator specification, equipment package, dimensions, and installation details should be confirmed before ordering.
Standard Marine Equipment and Configuration
The QLS 102T is supplied as an integrated marine diesel generator set. Depending on the production specification and installation package, typical equipment may include:
- Six-cylinder John Deere diesel engine
- Three-phase marine alternator
- Mechanical fuel-control system
- Marine cooling components
- Raw-water circulation equipment
- Wet-exhaust connections
- Fuel and oil filtration
- Generator protection equipment
- Flexible mounting system
- Operating and maintenance documentation
Optional equipment may include a sound enclosure, fuel-water separator, siphon-break equipment, remote monitoring, and installation accessories. Final inclusions should be confirmed during quotation because equipment packages can vary.
Genuine Nanni Supply and Worldwide Support
Customers looking for the New Nanni Generator Type QLS 102T Mechanical Marine Generator for sale can contact our marine specialists for current availability, technical documentation, installation guidance, and international delivery arrangements.
We support customers with:
- Genuine Nanni generator supply
- Electrical-load and sizing guidance
- Replacement-generator evaluation
- Marine application recommendations
- Export documentation
- Worldwide shipping
- After-sales assistance
Frequently Asked Questions
What is the Nanni QLS 102T Mechanical price?
The Nanni Generator Type QLS 102T Mechanical price depends on configuration, optional equipment, current availability, destination, and shipping requirements. Contact our team for an updated quotation.
How much power does the QLS 102T provide?
Nanni’s product guide lists 84.6 kW or 102.6 kVA of prime power, together with an additional published rating of 59 kW or 72 kVA. The applicable duty rating should be confirmed on the current technical sheet.
Is it a three-phase generator?
Yes. It is a 400V three-phase marine generator operating at 50 Hz and 1500 RPM.
What engine does it use?
It uses a turbocharged, six-cylinder John Deere diesel engine with approximately 6.8 litres of displacement, direct injection, and a mechanical fuel system.
Can it replace an existing commercial marine generator?
Yes, provided output, voltage, frequency, phase, dimensions, mounting, cooling, exhaust, fuel, and switchboard requirements are compatible.
Request a Quote for the Nanni QLS 102T Mechanical
The New Nanni QLS 102T Mechanical Marine Generator is a dependable choice for shipyards, vessel managers, yacht owners, and commercial operators requiring substantial three-phase marine power from a mechanically controlled John Deere diesel platform.
Contact our marine generator specialists to request the latest Nanni QLS 102T Mechanical price, confirm availability, review installation requirements, and select the correct configuration for your vessel.





Reviews